99
sub-base
non “plug-in”
sub-base
“plug-in”
sub-base
non “plug-in”
sub-base
“plug-in”
Series
82
Individual mounting
Manifold mounting
IN EXH
EXHAEXH B IN
• Unique patented MACSOLENOID
®
for fastest possible response times.
• Balanced poppet pilot valve for high flow, precise repeatability, and consistent operation.
• Large spool piston for maximum shifting force even at minimum operating pressure.
• Air/spring return for consistent shifting on single solenoid models.
• MAC spool and bore combination for wiping away contamination, eliminating sticking, and use on non-lube service.
• Patented virtually burn-out proof AC solenoid.
• Plug-in design of valves, bases, flow controls, and regulators for modular assembly and ease of maintenance.
• Optional low wattage DC solenoids down to 1.8 watts.
• Indicator lights in valve body or base and non-plug-in models available.
• Very high flow in a very compact package.
External pilot
supply port
Balanced poppet
Bonded spool
Large piston assembly
Indicator light
Encapsulated solenoid
Manual operator
Air/spring return
Direct solenoid and solenoid pilot operated valves
Series
SERIES FEATURES
Consult “Precautions” page 364 before use, installation or service of MAC Valves
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
82
100100
Series
82
SPOOL CONFIGURATIONS
EXHAEXH B IN
SINGLE OPERATOR
SINGLE INLET - DUAL EXHAUST
SHOWN WITH “B” OPERATOR ENERGIZED
BA
EXHAEXH B IN
DOUBLE OPERATOR
SINGLE INLET - DUAL EXHAUST
SHOWN WITH “B” OPERATOR ENERGIZED
BA
IN AAIN B B
EXH
SINGLE OPERATOR
DUAL INLET - SINGLE EXHAUST
SHOWN WITH “B” OPERATOR ENERGIZED
BA
IN AAIN B B
EXH
DOUBLE OPERATOR
DUAL INLET - SINGLE EXHAUST
SHOWN WITH “B” OPERATOR ENERGIZED
BA
EXHAEXH B IN
3 POSITION CLOSED CENTER
BA
EXHAEXH B IN
3 POSITION OPEN CENTER
BA
EXHAEXH B IN
3 POSITION SINGLE PRESSURE
PRESSURE CENTER
BA
IN AAIN B B
EXH
3 POSITION DUAL PRESSURE
PRESSURE CENTER
BA
Consult “Precautions” page 364 before use, installation or service of MAC Valves
18
18
100%
100%
100%
100%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
Consult “Precautions” page 364 before use, installation or service of MAC Valves
18
18
100%
100%
100%
100%
MONTHS
WARRANTY
OF
PRODUCTION
TESTED
101
Series
82
Function Port size Flow (Max) Individual mounting
4/2 - 4/3 1/8” - 1/4” - 3/8” 1.35 C
v
sub-base
non ”plug-in”
1. Balanced spool, immune to variations of pressure.
2. Short stroke with high flow.
3. The piston (booster) provides maximum shifting
forces.
4. Powerful return force thanks to the combination of
mechanical and air springs.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Wiping effect eliminates sticking.
7. Pilot valve with balanced poppet, high flow, short
and consistent response times.
8. Long service life.
* Other options available, see page 361.
82A-AB-000-TM-D
XXX-XXX
OPTIONS
- For dual pressure valves, replace A by C, B by D, E by M, F by L, G by H.
(Requires sandwich regulator, see pressure regulator section.)
82A-XX-BAA-TM-D
XXX-XXX
- Replace A by B for bottom ports (1/8” or 1/4” only)
- Replace A by C for side and bottom ports (1/8” or 1/4” only)
82A-AB-000-TM-D
XXX-XXX
- For pilot exhaust out main exhaust, replace B by E. Also, TM pilot body is replaced by TU pilot body.
- Main exhaust cannot be restricted. Available only on single pressure valves.
- TP (Piped pilot exhaust)
4/2
Single operator
82A-AB-000-TM-D
XXX-XXX
82A-AB-AAA-TM-D
XXX-XXX
82A-AB-AAD-TM-D
XXX-XXX
82A-AB-BAA-TM-D
XXX-XXX
82A-AB-BAD-TM-D
XXX-XXX
82A-AB-CAA-TM-D
XXX-XXX
82A-AB-CAD-TM-D
XXX-XXX
4/2
Double operator
82A-BB-000-TM-D
XXX-XXX
82A-BB-AAA-TM-D
XXX-XXX
82A-BB-AAD-TM-D
XXX-XXX
82A-BB-BAA-TM-D
XXX-XXX
82A-BB-BAD-TM-D
XXX-XXX
82A-BB-CAA-TM-D
XXX-XXX
82A-BB-CAD-TM-D
XXX-XXX
4/3
Closed center
82A-EB-000-TM-D
XXX-XXX
82A-EB-AAA-TM-D
XXX-XXX
82A-EB-AAD-TM-D
XXX-XXX
82A-EB-BAA-TM-D
XXX-XXX
82A-EB-BAD-TM-D
XXX-XXX
82A-EB-CAA-TM-D
XXX-XXX
82A-EB-CAD-TM-D
XXX-XXX
4/3
Open center
82A-FB-000-TM-D
XXX-XXX
82A-FB-AAA-TM-D
XXX-XXX
82A-FB-AAD-TM-D
XXX-XXX
82A-FB-BAA-TM-D
XXX-XXX
82A-FB-BAD-TM-D
XXX-XXX
82A-FB-CAA-TM-D
XXX-XXX
82A-FB-CAD-TM-D
XXX-XXX
4/3
Pressure center
82A-GB-000-TM-D
XXX-XXX
82A-GB-AAA-TM-D
XXX-XXX
82A-GB-AAD-TM-D
XXX-XXX
82A-GB-BAA-TM-D
XXX-XXX
82A-GB-BAD-TM-D
XXX-XXX
82A-GB-CAA-TM-D
XXX-XXX
82A-GB-CAD-TM-D
XXX-XXX
Port size
sub-base
1/8” NPTF
sub-base
1/4” NPTF
sub-base
3/8” NPTF
Pilot air
Internal
External
Internal
External
Internal
External
AABB
IN
EXH
AABB
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
Valve less base
Electrical connection
KA
Square connector
KD
Square connector with light
JB
Rectangular connector
JD
Rectangular connector with light
BA
Flying leads
Note : KD connector shown in photo.
D XX X- X XX
*
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
SOLENOID OPERATOR
³
XX X X XX
Series
Direct solenoid and solenoid pilot operated valves
OPERATIONAL BENEFITS
HOW TO ORDER
Consult “Precautions” page 364 before use, installation or service of MAC Valves
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
82
102
IN EXH
PILOT
IN
B
A
EXH
27,5
4,5
32,0
47,3
14,5
26,021,0
A
24,0
22,0
11,3
50,0
25,0
83,2
20,5
15,5
15,5
14,5
12,5
41,0
2 × Ø 5,3
32,027,5
26,021,0
80,0
9,0
A
CYL ACONDUIT
CYL B
PILOT
104,2
38,5
32,0
IN EXH
149,0 DOUBLE OPERATOR
OPTIONAL SANDWICH
FLOW CONTROLS
120,5 SINGLE OPERATOR
1/2-14 NPSM
Conduit port
1/8-27 NPTF
External pilot port
149,0 DOUBLE OPERATOR
120,5 SINGLE OPERATOR
Series
82
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Tem
perature range :
Flow (at 6 bar, ∆P=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Internal pilot : single operator and 3 positions : 25-150 PSI
do
uble operator : 10-150 PSI
External pilot : vacuum to 150 PSI
Single operator and 3 positions : 25-150 PSI Double operator : 10-150 PSI
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1/8” : (0.9 C
v
), 1/4" : (1.3 C
v
), 3/8" : (1.35 C
v
)
20
0
cm
3
/min
Epoxy encapsulated - class A wires - Continuous duty.
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W
24
VDC (5.4 W)
En
ergize : 9 ms
De
-energize : 6 ms
120/60
En
ergize : 5-12 ms
De
-energize :6-13 ms
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal between solenoid and pilot body : 16402. • Pilot valve : TM-DXXX-XXX, including seal 16447.
• Mounting screw pilot to main valve : 35023. • Pressure seal between valve and base : 16446.
• Mounting screw valve to base (x2) : 35211.
• BSPP threads. • Flow controls (Part N°. FC82A-BA) • Explosion-proof model.
Sp
are parts :
Options :
A
19.5 mm
17.0 mm
Port size
1/8” & 1/4” NPTF
3/8” NPTF
dimensions
technical data
Dimensions shown are metric (mm)
Consult “Precautions” page 364 before use, installation or service of MAC Valves
18
18
100%
100%
100%
100%
M O I S
GARANTIE
D E L A
P R O D U C T I O N
T E S T É E
18
18
100%
100%
100%
100%
M O N T H S
WARRANTY
O F
P R O D U C T I O N
T E S T E D
103
Series
82
Function Port size Flow (Max) Individual mounting
4/2 - 4/3 1/8” - 1/4” - 3/8” 1.35 C
v
sub-base
“plug-in”
1. Balanced spool, immune to variations of pressure.
2. Short stroke with high flow.
3. The piston (booster) provides maximum shifting
forces.
4. Powerful return force thanks to the combination of
mechanical and air springs.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Wiping effect eliminates sticking.
7. Pilot valve with balanced poppet, high flow, short
and consistent response times.
8. Long service life.
82A-AA-000-TM-D
XX
P
-X
DA
OPTIONS
- For light in body replace A by C.
- For pilot exhaust out main exhaust replace A by D. For light replace A by F.
Use TU pilot body for pilot exhaust to main exhaust, main exhaust cannot be restricted (NO flow controls) available with single
pressure valve only. TU replaces TM.
- For piped pilot exhaust replace TM by TP.
- For dual pressure valves, replace A by C, B by D, E by M, F by L, G by H.
(Requires sandwich regulator - see pressure regulator section)
82A-AA-BAA-TM-D
XX
P
-X
DA
- Replace A by B for bottom ports (1/8” or 1/4” only)
- Replace A by C for side and bottom ports (1/8” or 1/4” only)
4/2
Single operator
82A-AA-000-TM-D
XX
P-
X
DA
82A-AA-AAA-TM-D
XX
P-
X
DA
82A-AA-AAD-TM-D
XX
P-
X
DA
82A-AA-BAA-TM-D
XX
P-
X
DA
82A-AA-BAD-TM-D
XX
P-
X
DA
82A-AA-CAA-TM-D
XX
P-
X
DA
82A-AA-CAD-TM-D
XX
P-
X
DA
4/2
Double operator
82A-BA-000-TM-D
XX
P-
X
DA
82A-BA-AAA-TM-D
XX
P-
X
DA
82A-BA-AAD-TM-D
XX
P-
X
DA
82A-BA-BAA-TM-D
XX
P-
X
DA
82A-BA-BAD-TM-D
XX
P-
X
DA
82A-BA-CAA-TM-D
XX
P-
X
DA
82A-BA-CAD-TM-D
XX
P-
X
DA
4/3
Closed center
82A-EA-000-TM-D
XX
P-
X
DA
82A-EA-AAA-TM-D
XX
P-
X
DA
82A-EA-AAD-TM-D
XX
P-
X
DA
82A-EA-BAA-TM-D
XX
P-
X
DA
82A-EA-BAD-TM-D
XX
P-
X
DA
82A-EA-CAA-TM-D
XX
P-
X
DA
82A-EA-CAD-TM-D
XX
P-
X
DA
4/3
Open center
82A-FA-000-TM-D
XX
P-
X
DA
82A-FA-AAA-TM-D
XX
P-
X
DA
82A-FA-AAD-TM-D
XX
P-
X
DA
82A-FA-BAA-TM-D
XX
P-
X
DA
82A-FA-BAD-TM
-
-D
XX
P-
X
DA
82A-FA-CAA-TM-D
XX
P-
X
DA
82A-FA-CAD-TM-D
XX
P-
X
DA
4/3
Pressure center
82A-GA-000-TM-D
XX
P-
X
DA
82A-GA-AAA-TM-D
XX
P-
X
DA
82A-GA-AAD-TM-D
XX
P-
X
DA
82A-GA-BAA-TM-D
XX
P-
X
DA
82A-GA-BAD-TM-D
XX
P-
X
DA
82A-GA-CAA-TM-D
XX
P-
X
DA
82A-GA-CAD-TM-D
XX
P-
X
DA
Port size
sub-base
1/8” NPTF
sub-base
1/4” NPTF
sub-base
3/8” NPTF
Pilot air
Internal
External
Internal
External
Internal
External
AABB
IN
EXH
AABB
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
Valve less base
* Other options available, see page 361.
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Manual operator
1
Non-locking
2
Locking
D XX P- X DA
*
SOLENOID OPERATOR
³
XX X
Series
Direct solenoid and solenoid pilot operated valves
OPERATIONAL BENEFITS
HOW TO ORDER
Consult “Precautions” page 364 before use, installation or service of MAC Valves
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
82
104
IN EXH
PILOT
IN
B
A
EXH
27,5
4,5
32,0
47,3
14,5
26,021,0
A
24,0
22,0
11,3
50,0
25,0
83,2
20,5
15,5
15,5
14,5
12,5
41,0
2 × Ø 5,3
32,027,5
26,021,0
80,0
9,0
A
CYL ACONDUIT
CYL B
PILOT
104,2
38,5
3,9 (OPTION : light)
OPTIONAL
SANDWICH FLOW
CONTROLS
1/8” - 27 NPTF
EXTERNAL
PILOT
PORT
1/8”, 1/4”
(OPTIONAL BOTTOM
PORTS)
3,9 (OPTION : Light)
1/2” NPSM
149,0 DOUBLE OPERATOR
120,5 SINGLE OPERATOR
A
19.5
17.0
Port size
1/8” - 1/4”
3/8”
Series
82
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Tem
perature range :
Flow (at 6 bar, ∆P=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Internal pilot : single operator and 3 positions : 25-150 PSI
do
uble operator : 10-150 PSI
External pilot : vacuum to 150 PSI
Single operator and 3 positions : 25-150 PSI Double operator : 10-150 PSI
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1/8" : (0.9 C
v
), 1/4” (1.3 C
v
), 3/8" : (1.35 C
v
)
2
0
0 cm
3
/min
Epoxy encapsulated - class A wires - Continuous duty.
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W
24
VDC (5.4 W)
En
ergize : 9 ms
De
-energize : 6 ms
120/60
En
ergize : 5-12 ms
De
-energize :6-13 ms
• Solenoid operator (power ≥ 5.4 W ) : DXXP-XDA, including mounting screws 35013. • Seal between solenoid and pilot body : 16402.
• Pilot valve : TM-DXXP-XDA, including seal 16447. • Mounting screw pilot to main valve : 35023. • Pressure seal between valve and base : 16446.
• Mounting screw valve to base (x2) : 35211.
• BSPP threads. • Flow controls
(Part N°. FC82A-AA)
• Explosion-proof model. • Lights in base.
Spare parts :
Options :
dimensions
technical data
Dimensions shown are metric (mm)
Consult “Precautions” page 364 before use, installation or service of MAC Valves
18
18
100%
100%
100%
100%
M O I S
GARANTIE
D E L A
P R O D U C T I O N
T E S T É E
18
18
100%
100%
100%
100%
M O N T H S
WARRANTY
O F
P R O D U C T I O N
T E S T E D
105
Series
82
Function Port size Flow (Max) Manifold mounting
4/2 - 4/3 1/4” - 3/8” 1.35 C
v
sub-base
non “plug-in”
1. Balanced spool, immune to variations of pressure.
2. Short stroke with high flow.
3. The piston (booster) provides maximum shifting
forces.
4. Powerful return force thanks to the combination of
mechanical and air springs.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Wiping effect eliminates sticking.
7. Pilot valve with balanced poppet, high flow, short
and consistent response times.
8. Long service life.
* Other options available, see page 361.
4/2
Single operator
82A-AB-000-TM-D
XXX-XXX
82A-AB-BKA-TM-D
XXX-XXX
82A-AB-BKD-TM-D
XXX-XXX
82A-AB-CKA-TM-D
XXX-XXX
82A-AB-CKD-TM-D
XXX-XXX
4/2
Double operator
82A-BB-000-TM-D
XXX-XXX
82A-BB-BKA-TM-D
XXX-XXX
82A-BB-BKD-TM-D
XXX-XXX
82A-BB-CKA-TM-D
XXX-XXX
82A-BB-CKD-TM-D
XXX-XXX
4/3
Closed center
82A-EB-000-TM-D
XXX-XXX
82A-EB-BKA-TM-D
XXX-XXX
82A-EB-BKD-TM-D
XXX-XXX
82A-EB-CKA-TM-D
XXX-XXX
82A-EB-CKD-TM-D
XXX-XXX
4/3
Open center
82A-FB-000-TM-D
XXX-XXX
82A-FB-BKA-TM-D
XXX-XXX
82A-FB-BKD-TM-D
XXX-XXX
82A-FB-CKA-TM-D
XXX-XXX
82A-FB-CKD-TM-D
XXX-XXX
4/3
Pressure center
82A-GB-000-TM-D
XXX-XXX
82A-GB-BKA-TM-D
XXX-XXX
82A-GB-BKD-TM-D
XXX-XXX
82A-GB-CKA-TM-D
XXX-XXX
82A-GB-CKD-TM-D
XXX-XXX
Port size
sub-base
1/4” NPTF
sub-base
3/8” NPTF
Pilot air
Internal
External
Internal
External
AABB
IN
EXH
AABB
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
Valve less base
Electrical connection
KA
Square connector
KD
Square connectorwith light
JB
Rectangular connector
JD
Rectangular connector with
light
BA
Flying leads
D XX X - X XX
*
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Wire length
A
18” (Flying leads)
J
Connector
Manual operator
1
Non-locking
2
Locking
SOLENOID OPERATOR
³
XX X X XX
Note : KD connector shown in photo.
82A-AB-000-TM-D
XXX-XXX
OPTIONS
- For pilot exhaust out main exhaust replace B by E. Also, TM pilot body is replaced by TU pilot body. Main exhaust cannot be
restricted (No flow controls) available with single pressure valve only.
- For piped pilot exhaust replace TM by TP.
- For dual pressure valves, replace A by C, B by D, E by M, F by L, G by H.
(Requires sandwich regulator - see pressure regulator section)
82A-XX-BKA-TM-D
XXX-XXX
- Replace K by L for bottom cyl. ports
- Replace K by M for bottom inlet port
- Replace K by N for bottom inlet and cyl. ports
- Replace K by P for bottom and end cyl. ports
- Replace K by R for bottom and end cyl. ports w/bottom inlet
- Replace K by S for selector base with side ports
Series
Direct solenoid and solenoid pilot operated valves
OPERATIONAL BENEFITS
HOW TO ORDER
Consult “Precautions” page 364 before use, installation or service of MAC Valves
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
82
106
IN
EXH
EXH
COND
IN
COND
CYL A
CYL B
164,2
59,0
18,5
12,0
23,0
6,5
96,0
4,5
46,0 ± 0,2
22,5
37,0
2 × Ø 5,3
23,0
59,0
32,0
9,0
28,0
46,0
17,5
26,5 47,0
27,0
EXT PILOT
CYL B
CYL A
36,0
105,2
18,5
18,5
16
16,0
14,0
32,0
60,5
46,0
126,2
126,2
32
IN
EXH
COND
174,7 DOUBLE OPERATOR
164,2 SINGLE OPERATOR
174,7 DOUBLE OPERATOR
164,2 SINGLE OPERATOR
1/8”- 27 NPTF
(OPTIONAL
COMMON EXT. PILOT PORT)
1 1/4” NPSM
3/8” - 4 PLACES
OPTIONAL SANDWICH
FLOW
CONTROLS
1/8”
Series
82
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Tem
perature range :
Flow (at 6 bar, ∆P=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Internal pilot : single operator and 3 positions : 25-150 PSI double operator : 10-150 PSI
External pilot : vacuum to 150 PSI
Single operator and 3 positions : 25-150 PSI Double operator : 10-150 PSI
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1/4” (1.3 C
v
), 3/8" : (1.35 C
v
)
2
0
0 cm
3
/min
Epoxy encapsulated - class A wires - Continuous duty.
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W
24
VDC (5.4 W) Energize : 9 ms De-energize : 6 ms
120/60 Energize : 5-12 ms De-energize :6-13 ms
• Solenoid operator (power ≥ 5.4 W) : DXXX-XXX, including mounting screws 35013.
• Seal between solenoid and pilot body : 16402. • Pilot valve : TM-DXXX-XXX, including seal 16447.
• Mounting screw pilot to main valve : 35023. • Pressure seal between valve and base : 16446.
Mounting screw valve to base (x2) : 35211. • Tie-rod (x2) : 19731. •-Fastening kit : N-82005-01.
• BSPP threads. • Flow controls (Part N°. FC82A-BA)
Explosion-proof model.
Sp
are parts :
Options :
dimensions
technical data
Dimensions shown are metric (mm)
Consult “Precautions” page 364 before use, installation or service of MAC Valves
18
18
100%
100%
100%
100%
M O I S
GARANTIE
D E L A
P R O D U C T I O N
T E S T É E
18
18
100%
100%
100%
100%
M O N T H S
WARRANTY
O F
P R O D U C T I O N
T E S T E D
107
Series
82
Function Port size Flow (Max) Manifold mounting
4/2 - 4/3 1/4” - 3/8” 1.35 C
v
sub-base
“plug-in”
1. Balanced spool, immune to variations of pressure.
2. Short stroke with high flow.
3. The piston (booster) provides maximum shifting
forces.
4. Powerful return force thanks to the combination of
mechanical and air springs.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Wiping effect eliminates sticking.
7. Pilot valve with balanced poppet, high flow, short
and consistent response times.
8. Long service life.
4/2
Single operator
82A-AA-000-TM-D
XX
P-
X
DA
82A-AA-BKA-TM-D
XX
P-
X
DA
82A-AA-BKD-TM-D
XX
P-
X
DA
82A-AA-CKA-TM-D
XX
P-
X
DA
82A-AA-CKD-TM-D
XX
P-
X
DA
4/2
Double operator
82A-BA-000-TM-D
XX
P-
X
DA
82A-BA-BKA-TM-D
XX
P-
X
DA
82A-BA-BKD-TM-D
XX
P-
X
DA
82A-BA-CKA-TM-D
XX
P-
X
DA
82A-BA-CKD-TM-D
XX
P-
X
DA
4/3
Closed center
82A-EA-000-TM-D
XX
P-
X
DA
82A-EA-BKA-TM-D
XX
P-
X
DA
82A-EA-BKD-TM-D
XX
P-
X
DA
82A-EA-CKA-TM-D
XX
P-
X
DA
82A-EA-CKD-TM-D
XX
P-
X
DA
4/3
Open center
82A-FA-000-TM-D
XX
P-
X
DA
82A-FA-BKA-TM-D
XX
P-
X
DA
82A-FA-BKD-TM-D
XX
P-
X
DA
82A-FA-CKA-TM-D
XX
P-
X
DA
82A-FA-CKD-TM-D
XX
P-
X
DA
4/3
Pressure center
82A-GA-000-TM-D
XX
P-
X
DA
82A-GA-BKA-TM-D
XX
P-
X
DA
82A-GA-BKD-TM-D
XX
P-
X
DA
82A-GA-CKA-TM-D
XX
P-
X
DA
82A-GA-CKD-TM-D
XX
P-
X
DA
Port size
sub-base
1/4” NPTF
sub-base
3/8” NPTF
Pilot air
Internal
External
Internal
External
AABB
IN
EXH
AABB
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
ABBA
IN
EXH
Valve less base
* Other options available, see page 361.
Voltage
AA
120/60, 110/50
AB
240/60, 220/50
AC
24/60, 24/50
FB
24 VDC (1.8 W)
DA
24 VDC (5.4 W)
DF
24 VDC (12.7 W)
Manual operator
1
Non-locking
2
Locking
D XX P- X DA
*
SOLENOID OPERATOR
³
XX X
82A-XX-BKA-TM-D
XX
P
-X
DA
- Replace K by L for bottom cyl. ports
- Replace K by M for bottom inlet port
- Replace K by N for bottom inlet and cyl. ports
- Replace K by P for bottom and end cyl. ports
- Replace K by R for bottom and end cyl. ports w/bottom inlet
- Replace K by S for selector base with side ports
82A-AA-000-TM-D
XX
P
-X
DA
OPTIONS
- For light in body replace A by C.
- For pilot exhaust out main exhaust replace A by D. For light replace A by F.
Use TU pilot body for pilot exhaust to main exhaust, main exhaust cannot be restricted (No flow controls) available with single
pressure valve only. TU replaces TM.
- For piped pilot exhaust replace TM by TP.
- For dual pressure valves, replace A by C, B by D, E by M, F by L, G by H.
(Requires sandwich regulator - see pressure regulator section)
Series
Direct solenoid and solenoid pilot operated valves
OPERATIONAL BENEFITS
HOW TO ORDER
Consult “Precautions” page 364 before use, installation or service of MAC Valves
35
100
200
55
56
57
58
59
45
700
900
82
6300
6500
6600
1300
800
ISO 1
ISO 2
ISO 3
MAC 125A
MAC 250A
MAC 500A
82
108
IN
EXH
EXH
COND
IN
COND
CYL A
CYL B
164,2
59,0
18,5
12,0
23,0
6,5
96,0
4,5
46,0 ± 0,2
22,5
37,0
2 × Ø 5,3
23,0
59,0
32,0
9,0
28,0
46,0
17,5
26,5 47,0
27,0
32,0
126,2
EXT PILOT
CYL B
CYL A
36,0
105,2
18,5
18,5
16
16,0
14,0
60,5
46,0
126,2
IN
EXH
COND
174,7 DOUBLE OPERATOR
164,2 SINGLE OPERATOR
174,7 DOUBLE OPERATOR
164,2 SINGLE OPERATOR
1 1/4” NPSM
1/8”
(OPTIONAL COMMON
EXT. PILOT PORT.)
OPTIONAL SANDWICH
FLOW
CONTROLS
3/8” - 4 PLACES
1/8”
Series
82
Fluid :
Pressure range :
Pilot pressure :
Lubrication :
Filtration :
Tem
perature range :
Flow (at 6 bar, ∆P=1bar) :
Leak rate :
Coil :
Voltage range :
Protection :
Power :
Response times :
Compressed air, vacuum, inert gases
Internal pilot : single operator and 3 positions : 25-150 PSI
do
uble operator : 10-150 PSI
External pilot : vacuum to 150 PSI
Single operator and 3 positions : 25-150 PSI Double operator : 10-150 PSI
Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
40 µ
0°F to 120°F (-18°C to 50°C)
1/4” (1.3 C
v
), 3/8" : (1.35 C
v
)
20
0
cm
3
/min
Epoxy encapsulated - class A wires - Continuous duty.
-15% to +10% of nominal voltage
Consult factory
Inrush : 10.9 VA
Holding : 7.7 VA
= 1.8 to 12.7 W
24
VDC (5.4 W)
En
ergize : 9 ms
De
-energize : 6 ms
120/60
En
ergize : 5-12 ms
De
-energize :6-13 ms
• Solenoid operator (power ≥ 5.4 W) : DXXP-XDA, including mounting screws 35013.
• Seal between solenoid and pilot body : 16402. • Pilot valve : TM-DXXP-XDA, including seal 16447.
• Mounting screw pilot to main valve : 35023. • Pressure seal between valve and base : 16446.
• Mounting screw valve to base (x2) : 35211. • Tie-rod (x2) : 19731. • Fastening kit : N-82005-01.
• BSPP threads. • Flow controls
(Part N°. FC82A-AA)
• Explosion-proof model. • Lights in base.
Spare parts :
Options :
dimensions
technical data
Dimensions shown are metric (mm)
Consult “Precautions” page 364 before use, installation or service of MAC Valves
18
18
100%
100%
100%
100%
M O I S
GARANTIE
D E L A
P R O D U C T I O N
T E S T É E
18
18
100%
100%
100%
100%
M O N T H S
WARRANTY
O F
P R O D U C T I O N
T E S T E D
347
Series
82
SPOOL TYPE - VALVE FUNCTION
0 Individual base or manifold only
A Single Operator - single pressure
B Double operator - sinle pressure
C Single operator - dual pressure
D Double operator - dual pressure
E 3-position closed center
F 3-position open center
G 3-position single pressure, pressure center
H 3-position dual pressure,* pressure center
J Single solenoid single pressure
solenoid on B end
K Single solenoid dual pressure
solenoid on B end
L 3-position dual pressure,* open center
M 3-position dual pressure,* closed center
* Note: For dual pressure w/o regulators consult
factory.
82A - XX - XXX - (XX - DXXX - XXX)
BODY
OPTIONS
IND. & MANIFOLD BASE PORT CONFIG.
--Individ ual Base--
0 Valve only - no base
A Standard side ports (1/8”, 1/4”, or 3/8”)
B Bottom ports only*
C Side and bottom ports*
D Side inlet, side exhaust, bottom cylinder ports*
* Bottom ports available in 1/8” & 1/4” only in individual
base
--Manifold Base--
K Standard ports (1/4” or 3/8” only)
L Bottom cylinder ports*
M Bottom inlet port
N Bottom inlet and cylinder ports*
P Bottom and end cylinder ports*
R Bottom cylinder & end cylinder ports w/bottom inlet port*
S Selector base - standard side ports
* Bottom parts available in 1/4” & 3/8” only on manifold.
Bottom inlet available 1/4” only.
For bottom O-ring ports, consult factory.
BASE
OPTIONS
PILOT
VALVE
INT. OR EXT. PILOT*
--Internal Pilot--
0 Valve only - no base
A No light in base
--External Pilot--
0 Valve only - no base
D No light in base
* Use internal for main valve
pressures of 25-150 PSIG. Use
external for main valve pressures
of 28” Hg vacuum - 25 PSIG
PILOT VALVE OPTIONS - (XX - DXXX - XXX)
BODY TYPE
A Plug-in body
B Non Plug-in body
PORT SIZE - THREAD TYPE
0 Valve only - no base
A 1/8” NPTF
B 1/4” NPTF
C 3/8” NPTF
D 1/8” BSPPL
E 1/4” BSPPL
F 3/8” BSPPL
PILOT EXHAUST
FA Muffled exhaust
LEAD WIRE LENGTH
--Plug-in Valve/Base--
P Plug-in 8” - standard
1 18” 4 48”
2 24” 5 72”
3 36” 6 96”
--Non Plug-in Valve/Base--
A 18” E 72”
B 24” F 96”
C 36” J 6”*
D 48”
* Lead wire length for external
plug-in connectors must be “J”
ELECTRICAL CONN.
--Plug-in Valve/Base--
DA Plug-in (standard)
--Non Plug-in Valve/Base--
BA Grommet
CA Conduit 1/2” NPS
CM Metal conduit 1/2” NPS
CN Metal conduit w/grd.
1/2” NPS
--External Plug-in--
JB Rectangular plug-in
JM Rectangular male only
KA Mini plug-in
KJ Mini plug-in male only
TA Dual tabs (.110) w/
receptables
TJ Dual tabs (.110) w/o
receptables
VOLTAGE
FR 12VDC (0,6w)
FS 24VDC (0,6w)
MANUAL OPERATOR
0 No manual operator
1 Nonlocking operator
2 Locking operator
3 Nonlocking extended operator
4 Locking extended operator
HOW TO ORDER 82 SERIES FLOW CONTROL MODULE*
NOTE: Reference regulator ordering section if a
sandwich regulator is required.
NOTE: If a flow control assembly is used with the dual
pressure regulator option, only the flow control on the
“A” end is functional. (Controls both cylinder ports.)
FC 82A-AA
FC 82A-BA
Plug-in flow control assembly
Non plug-in flow control assembly
*If flow control module is to be installed between valve and base or valve and manifold at the factory,
add -9 after the flow control model number, i.e., FC82A-AA-9. The flow control model number
should follow the valve model number on which it is to be installed.
Intrinsically Safe Valves
HOW TO ORDER
Consult “Precautions” page 364 before use, installation or service of MAC Valves
361
OPTIONS
Codification table for voltages / Wire length / Manual operators / Electrical connections
- D XX X - X XX
1 2 3 4
VALVE CODE
³
OPTIONS AVAILABLE FOR
- Solenoid valves 35, 45 and 82 Series
Consult “Precautions” page 364 before use, installation or service of MAC Valves
O p t i o n s
362
OPTIONS
1. VOLTAGE
- D XX X - X XX VOLTAGE
AA 120/60, 110/50
AB 240/60, 220/50
AC 24/60, 24/50
AD 24/60
AE 200/60
AF 240/50
AG 100/50, 100/60, 110/60
DA 24 VDC (5.4 W)
DB 12 VDC (5.4 W)
DC 12 VDC (7.5 W)
DD 24 VDC (7.3 W)
DE 12 VDC (12.7 W) - CLSFonly
DF 24 VDC (12.7 W) - CLSF only
DK 110 VDC (4.7 W)
DL 64 VDC (6 W)
DM 36 VDC (5.3 W)
DN 6 VDC (6 W)
DP 48 VDC (5.8 W)
DU 24 VDC (6 W)
EA 12 VDC (6 W)
FA 12 VDC (1.8 W)
FB 24 VDC (1.8 W)
FE 12 VDC (2.4 W)
FF 24 VDC (2.4 W)
2. WIRE LENGTH
- D XX X - X XX WIRE LENGTH
A 18”
B 24”
C 36”
D 48”
E 72”
F 96”
J For external plug-in connector (“J”, “K” & “T” type electrical connection)
P For plug-in valves (82 Series only)
Consult “Precautions” page 364 before use, installation or service of MAC Valves
363
O P T I ONS
3. MANUAL OPERATOR
- D XX X - X XX MANUAL OPERATOR
0 No operator
1 Non-locking recessed
2 Locking recessed
3 Non-locking extended
4 Locking extended
4. ELECTRICAL CONNECTION
- D XX X - X XX ELECTRICAL CONNECTION
BA Flying leads
BK BA with protection diode
BL BA with protection varistor (M.O.V.)
** CA 1/2" NPS conduit
** CM 1/2" NPS metal conduit
** CN 1/2" NPS metal conduit w/ground
** JB Rectangular connector
** JD Rectangular connector with light
** JM Rectangular connector, male only
KA Square connector
KB Square connector with protection diode
KC Square connector with protection varistor (M.O.V.)
KD Square connector with light
KE Square connector with light and protection diode
KF Square connector with light and protection varistor (M.O.V.)
KG Square connector with LED light & diode
KJ Square connector (male only)
KK Square connector with protection diode (male only)
KL Square connector with protection varistor (male only) (M.O.V.)
TA Dual tabs
TB TA with protection diode
TD TA with light
TE TA with light and protection diode
TJ Dual tabs (male only)
TK TJ with protection diode
TM TJ with light
TN TJ with light and protection diode
DA* Plug-in connector
DK* DA with protection diode
DL* DA with protection varistor (M.O.V.)
FM Plug-in
FN Plug-in with diode
FP Plug-in with M.O.V.
* To be used with 82 Series only
** Inline valves only for 35 & 45 series. No restrictions for 82 series.
Consult “Precautions” page 364 before use, installation or service of MAC Valves
O p t i o n s